Wall Plan - Components / Labeling

Show adjacent walls and beams: The members from adjacent walls and ceilings up to a distance of 0.5 m can be shown.

Show roof structure: The timbers from the roof up to a distance of 0.5 m from the respective wall can be shown.

Display ceiling beams in sections: With this switch the ceiling beams can also be displayed in the sections.

Display roof structure in section areas: With this switch the roof structure can also be displayed in the section areas.

Display mounting threshold: The display of thresholds with the member type '623/Montageschwelle' can be controlled here. This allows the lowest threshold of the wall, when used as a mounting threshold, to be switched off for the plan storage.

Plate labeling parallel to span direction: With this switch you can align the plate labels parallel to the span direction (= X axis) of the plate. If this option is switched off, the plate label is always generated so that it is readable from below, regardless of the plate's span direction.

Display from the back 1st view: As described further below there are 3 view settings. Here you can set for the 1st view whether it displays the wall from the front (in viewing direction) or from the back (opposite viewing direction).

Display from the back 2nd view: As described further below there are 3 view settings. Here you can set for the 2nd view whether it displays the wall from the front (in viewing direction) or from the back (opposite viewing direction).

Display from the back, positive layers single view: As described further below there are 3 view settings. The third view setting is for the individual views of the layers, meaning each of the layers enabled there is displayed individually on the plan. Here you can set for the positive layers whether they should be displayed from the back or from the front. The negative layers are always displayed from the front in the individual views.

Display section areas in the individual views: In most cases the section areas are only shown in the main plans 1 and 2. With this switch they can also be displayed in the individual views.

Display auxiliary components: Normally auxiliary components are not shown on a plan. With this switch these auxiliary components can nevertheless be displayed on the plan.

Label ceiling beams: If this option is enabled, the ceiling beams also receive a label as configured for the respective component group.

Label purlins: If this option is enabled, the purlins also receive a label as configured for the respective component group.

Views / layer contours: Here you enable the construction groups that should be displayed in the plan.

The group switching distinguishes three displays here:

On the one hand you can configure the groups to be displayed for the 1st view, which can also receive the vertical and horizontal sections. In this view one or several levels can thus be displayed at once.

The 2nd view behaves exactly like the 1st view. It can contain multiple groups at once and also receives the horizontal and vertical sections. For both views (1 and 2) the display from the back can also be set separately. This allows two views with multiple groups each to be created, one showing the wall from the front and the other from the back.

In addition, each level can be displayed in its own view. These views are inserted in a separate window during automatic plan generation (with plan template). For which levels a separate view should be generated can be set with the 3rd column of checkboxes.

Layer contours: The last column of checkboxes (L) enables the display of layer contours. The contours of the enabled layers are displayed in views 1 and 2.

Labeling: In this field you can set the component labeling for the respective group. You select one of the saved settings that defines how the component labeling should be generated. With the icon to the right of the field you can review and modify the settings. If you do not want a label for a group, select the setting 'no setting'.

Profile member labeling: Specifically for profile members you can choose a different labeling setting. Independently of the group's labeling setting to which the profile member belongs, it will then be labeled with the setting chosen here.

Fitting labeling: Specifically for fittings you can choose a different labeling setting. Independently of the group's labeling setting to which the fitting belongs, it will then be labeled with the setting chosen here.

Labeling in views 1 and 2, groups: The labels set above apply to the respective group. Since the individual groups can be displayed in the main plans 1 and 2, as well as in individual views, here you can specify which groups should be labeled in the main plans 1 and 2.

Labeling in individual views for groups: The labels set above apply to the respective group. Since the individual groups can be displayed in the main plans 1 and 2, as well as in individual views, here you can specify which groups should be labeled in the individual views.

Measurement units: In this field you select the setting for the measurement units. You can review and modify the settings using the icon to the right of the field.

Hatches and fills for 1st view: Here you can choose a hatch setting for the 1st view.

Hatches and fills for 2nd view: Here you can choose a hatch setting for the 1st view.

Hatches and fills for individual views: Here you can choose a hatch setting for the 1st view.

Hatches and fills for wall sections: Here you can choose a hatch setting for the 1st view.

Last updated